← All equipment and softwareAnchor load cells
Anchor load cells

DAGG Anchor load cell

Monitors force in ground anchors and bracing structures. Used to monitor excavation supports, retaining walls, and sheet-pile walls.

DAGG Anchor load cell
Application

Application and connection

Measures ground-anchor tension during service. Installed in a spacer between the bearing plate and the spherical anchor nut, the load cell experiences compression equal to the anchor tensile force.

Can monitor tensile loads in diaphragm-wall, retaining-wall, and sheet-pile anchors, as well as compressive loads in excavation struts.

Parameters

Technical specifications

Output
DAGG-D01: Digital DAGG-01: Analog bridge
Force measurement range, kN
250/500/750/1000/1500/2000/3000
Basic measurement error, % of span
1
Operating temperature range, °C
-50…+60
Ingress protection
IP68
Sensor material
Stainless steel
Interface
DAGG-D01: RS-485 DAGG-01: -
Communication protocol
DAGG-D01: Modbus DAGG-01: -

Key manufacturer data is shown. Range, interfaces, and supplied components depend on the selected version.