PLLG D01 Water level sensor
Measures groundwater levels in observation boreholes. Transmits readings over RS-485 for long-term monitoring of foundations, hydraulic facilities, and slopes.

Application and connection
Submerged in an open observation borehole for long-term groundwater level measurements. Suitable for geotechnical monitoring, hydraulic structures, and landslide slopes.
The D01 electronic unit is built into the sensor. It communicates with the acquisition system over RS-485 / Modbus. Selection accounts for pressure range, atmospheric pressure compensation, and required measurement error.
Technical documentation
Operating manual (RU)On the manufacturer’s website (RU)Technical specifications
- Mounting method
- Submersion
- Gauge pressure range, bar (atmospheric compensation)
- 0.1/0.2/0.3/1/2/3
- Relative pressure range, bar (without atmospheric compensation)
- 5/6/10/20/30
- Filter element type
- LAE — pore size 50 µm
- Maximum sensor dimensions (length × diameter), mm
- 225 ×23
- Housing material
- Stainless steel
- Operating temperature range (piezometer)
- -10…60 °C
- Operating temperature range (electronic unit)
- -45…60 °C
- Pressure error relative to full scale
- Version …-01-…: ±0.1 % Version …-05-…: ±0.5 %
- D01 interface
- RS-485, Modbus; built-in electronic unit
- Power supply
- 9–28 V
Key manufacturer data is shown. Range, interfaces, and supplied components depend on the selected version.
Full manufacturer data (RU)Let’s discuss your task
Tell us about the facility, the current system, and what needs to change. We will clarify the details and suggest the next step.