Data acquisition equipment
CU-GPRS Data acquisition and transmission module
Polls sensors, stores measurements, and sends them over GPRS cellular networks. The version is selected for the input signals and installation conditions.

Application
Application and connection
Collects, stores, and transmits measurements over GPRS from NTP Gorizont instruments, third-party analog vibrating-wire sensors, and third-party digital sensors with RS-485 outputs.
Can operate as a standalone logger using its own memory or as a terminal that transmits stored data over cellular networks.
Parameters
Technical specifications
- Input, RS485 version
- Digital RS-485 / Modbus sensors
- Input, 1VW–4VW versions
- 1 to 4 analog vibrating-wire sensors, depending on model
- Housing and protection
- CU-GPRS-1: ABS, IP65 CU-GPRS-2: aluminum, IP65 CU-GPRS-3: stainless steel, IP68
- Installation
- CU-GPRS-1: indoors or in borehole head CU-GPRS-2: outdoors CU-GPRS-3: in borehole
- Operating temperature
- −45…+50 °C
- Memory
- Flash, 10 MB, FAT16
- Archive export
- USB
- Power source
- 3.6 V battery modules; configuration depends on version
Key manufacturer data is shown. Range, interfaces, and supplied components depend on the selected version.
Full manufacturer data (RU)Descriptions, specifications, and images: NTP Gorizont materials.Manufacturer resources (RU) ↗