← All equipment and softwareSettlement sensors
Settlement sensors

HSSG Hydrostatic level sensor

Measures vertical displacement and structural settlement from changes in liquid levels in connected vessels. Suitable for foundations, hydraulic structures, and geotechnical monitoring.

HSSG Hydrostatic level sensor
Application

Application and connection

Measuring vessels are connected by a hydrostatic line. When parts of a structure move vertically, the liquid levels change; the system determines settlement from this difference.

Used to monitor foundations, piles, hydraulic structures, and buildings near tunnels. Data is collected over RS-485; wireless transmission requires separate acquisition modules.

Parameters

Technical specifications

Vertical displacement range
Lower limit: 0 mm; upper limit: 100 to 250 mm, depending on version
Basic error
0.1 % of measurement span
Monitoring points
≥ 2
Interface
RS-485
Hydrostatic line length
≤ 200 m
Power supply
9–28 V DC
Operating temperature
−50…+50 °C
Enclosure protection
IP65
Maximum transducer dimensions
HSSG-D01-250: Ø38 × 530 mm HSSG-D01-500: Ø38 × 780 mm
Maximum transducer mass
HSSG-D01-250: 2 kg HSSG-D01-500: 3 kg

Key manufacturer data is shown. Range, interfaces, and supplied components depend on the selected version.

Full manufacturer data (RU)

Document for Kazakhstan

Recognition of type approval for the HSSG-D measuring instrument, certificate No. 2845. Valid until 28.03.2030.

Download certificate (RU)
Descriptions, specifications, and images: NTP Gorizont materials.Manufacturer resources (RU) ↗