← All equipment and softwareTemperature sensors and strings
Temperature sensors and strings

THLG-D11 RS-485 thermistor string

Measures the temperature profile of soil or structures at multiple points. Transmits readings over RS-485 / Modbus.

THLG-D11 RS-485 thermistor string
Application

Application and connection

Its RS-485 digital output connects multiple thermistor strings over distances up to 800 m without intermediate controllers or converters. Strings can share the line with other NTP Gorizont instruments.

An armored cable is available on request.

Parameters

Technical specifications

Measurement range, °C
-50…+85
Readout resolution, °C
0.01
Number of temperature sensors
≤ 250
Temperature sensor spacing, m
0.5 ; 1; 2
Digital output
RS-485 (modbus)
Data rate
9600 bit/s
Supply voltage
9-28 V
Current consumption at 24 V, mA
2
Absolute error by temperature interval
(−50; −40] °C: ±0.3 °C (−40; −10] °C: ±0.2 °C (−10; +10] °C: ±0.1 °C (+10; +85] °C: ±0.2 °C

Key manufacturer data is shown. Range, interfaces, and supplied components depend on the selected version.

Full manufacturer data (RU)
Descriptions, specifications, and images: NTP Gorizont materials.Manufacturer resources (RU) ↗